Electric Alarm Valve For Dry Pipe Sprinkler System
SANJING FIRE electric alarm valve for a dry pipe sprinkler system is a type of valve that is used to control the flow of water in the system and to activate an alarm in the event of a fire.
SANJING FIRE electric alarm valve for a dry pipe sprinkler system is a type of valve that is used to control the flow of water in the system and to activate an alarm in the event of a fire. It is designed to automatically open when a fire is detected and to close when the fire is extinguished.
The electric alarm valve is typically connected to the building's fire alarm system, which monitors the system for signs of a fire. When the fire alarm is triggered, the electric alarm valve opens, allowing water to flow through the sprinkler heads and extinguish the fire. At the same time, the valve activates an alarm to alert building occupants and the fire department of the emergency.
One of the advantages of using an electric alarm valve in a dry pipe sprinkler system is that it can help to reduce the response time of the system. Unlike traditional pneumatic valves, which can take several seconds to open after a fire is detected, electric alarm valves can open almost immediately, helping to minimize the spread of the fire and reduce damage to the building.
Electric alarm valves are typically used in commercial and industrial buildings where the risk of fire is high and a rapid response is critical. They may also be required by local building codes and regulations. Regular maintenance and testing of the electric alarm valve and the entire dry pipe sprinkler system is essential to ensure that they are functioning properly and will operate as intended in the event of a fire.
Parameter
1) Size: DN50 / DN65 / DN80 / DN100 / DN125 / DN150 / DN200 / DN250
2) Flange holes match to: PN16 / BS4504 / EN1092 / DIN2502 / ANSI150lb
3) Rated working pressure: 1.6MPa / 16bar / 235psi
4) Material: ductile cast iron body, rubber seal, galvanized accessory pipe, brass accessory valves
5) With all fittings include water motor bell, pressure switch, pressure gauge, solenoid valve etc.
|
Size |
DN80 |
DN100 |
DN125 |
DN150 |
DN200 |
DN250 |
|
Starting Time (s) |
≤15 |
≤60 |
||||
|
Friction Resistance |
≤0.07 |
|||||
|
Height of Alarm Valve (mm) |
330 |
350 |
430 |
500 |
||
|
Outside Diameter of Flange (mm) |
200 |
220 |
250 |
285 |
340 |
405 |
|
Diameter Between Flange Screw Hole (mm) |
160 |
180 |
210 |
240 |
295 |
355 |
|
Diameter of Flange Holes (mm) |
8 |
12 |
||||
|
Quantity of Screw Hole |
18 |
22 |
26 |
|||

Q&A
Q: Which certificate do you have?
A: CE, FDA and ISO13485.
Q: Do you have the test and audit service?
A: Yes, we can assist to get the designated test report for product and the designated factory audit report.
Q: What’s is your shipping service?
A: We can provide services for vessel booking, goods consolidation, customs declaration, shipping documents preparation and delivery bulk at the shipping port.